CVE-2026-55473
Severity not reportedHomeBox is a home inventory and organization system.
HomeBox is a home inventory and organization system. Prior to 0.26.0, the default-on BlockBogonNets and BlockCloudMetadata notifier SSRF protections in backend/internal/sys/validate/notifier_url.go do not inspect IPv4 destinations embedded in the NAT64 prefixes 64:ff9b::/96 and 64:ff9b:1::/48. An authenticated user can submit a generic:// notifier through POST /v1/notifiers or POST /v1/notifiers/test, and on a Homebox instance that egresses through NAT64/DNS64, the gateway can translate an accepted IPv6 destination to cloud metadata, localhost, or another internal IPv4 host. The notifier test path returns delivery result information, and Shoutrrr propagates the response, providing feedback that can disclose retrieved metadata such as temporary credentials. Without NAT64 egress, the crafted IPv6 destination is not routable, but the guard still incorrectly classifies it as safe. This issue is fixed in version 0.26.0.
Affected products
Not reported by the source (unknown — not "none").
Weakness classification (CWE)
Source: NVD / CISA. “NVD-CWE-Other” and “NVD-CWE-noinfo” mean NVD could not assign a specific weakness.
Mitigation & advisories
No vendor advisory or patch reference tagged by NVD. Check the references below.
References
- https://github.com/sysadminsmedia/homebox/commit/42c52f7f7566b7fbd8017352187af20f552a4471 security-advisories@github.com
- https://github.com/sysadminsmedia/homebox/releases/tag/v0.26.0 security-advisories@github.com
- https://github.com/sysadminsmedia/homebox/security/advisories/GHSA-r9pf-rg22-655m security-advisories@github.com