highA security vulnerability has been detected in BioStar Temperature Monitor Utility 1.2.1806.2200.
A security vulnerability has been detected in BioStar Temperature Monitor Utility 1.2.1806.2200. Affected by this vulnerability is the function sub_1105C of the file BS_HWMIO64_W10.sys of the component IOCTL Handler. Such manipulation of the argument PhysicalAddress leads to write-what-where condition. The attack needs to be performed locally. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H Affected products
Not reported by the source (unknown — not "none").
Weakness classification (CWE)
Source: NVD / CISA. “NVD-CWE-Other” and “NVD-CWE-noinfo” mean NVD could not assign a specific weakness.
Mitigation & advisories
No vendor advisory or patch reference tagged by NVD. Check the references below.